Flow Cytometry Products

Microsphere

Flow Cytometry Products

Going with the flow.

Full Spectrum™

Full Spectrum™ microspheres provide a convenient means for performing the initial daily QC check on 3-6 color instruments. These ~7-9µm microspheres are internally labeled with multiple fluorophores for use with common excitation and detection wavelengths within the visible spectrum. Full Spectrum™ are available in three sizes: A (20 tests), B (100 tests), and C (280 tests).

Catalog Code Description Product Data Sheet Material Safety Data Sheet
885 Full Spectrum™
PDS 885.pdf MSDS 885.pdf

Fluorescence Reference Standards

Single-color Fluorescence Reference Standards are labeled with specific fluorochromes to exhibit the same spectral characteristics as labeled cells. Their size approximates that of human lymphocytes (~7-9µm in diameter) and are available in a wide vareity of fluorescent dyes. Both the fluorescein and propidium iodide are also available as 2µm beads. These standards may be used to QC a specific path of the optical system (laser/filter/PMT), to optimize filter and mirror sets for fluorophores, and to establish a test-specific Target Channel Value for instrument set-up. Fluorescence References Standards are available in three sizes: A (20 tests), B (100 tests), and C (280 tests).

Catalog Code Description Product Data Sheet Material Safety Data Sheet
890 Certified Blank™
PDS 890.pdf MSDS 890.pdf
910 Autofluor™ PDS 890.pdf MSDS 910.pdf
897 Acridine Orange PDS 890.pdf MSDS 897.pdf
901 Allophycocyanine (APC) PDS 890.pdf MSDS 901.pdf
914 APC-Cy™7 PDS 890.pdf MSDS 914.pdf
898 Chlorophyll PDS 890.pdf MSDS 898.pdf
896 Dansyl Chloride PDS 890.pdf MSDS 896.pdf
906 DAPI PDS 890.pdf MSDS 906.pdf
913 Far-Out Red PDS 890.pdf MSDS 913.pdf
891 Fluorescein (FITC)
PDS 890.pdf MSDS 891.pdf
851 Fluorescein (FITC), 2µm PDS 890.pdf MSDS 851.pdf
903 Fura 2 PDS 890.pdf MSDS 903.pdf
894 Hoechst 33342 PDS 890.pdf MSDS 894.pdf
902 Indo 1 PDS 890.pdf MSDS 902.pdf
900 Oxazine 1 PDS 890.pdf MSDS 900.pdf
908 PE-Cy™5 PDS 890.pdf MSDS 908.pdf
889 PE-Cy™7 PDS 890.pdf MSDS 889.pdf
909 PE-TR PDS 890.pdf MSDS 909.pdf
892 Propidium Iodide PDS 890.pdf MSDS 892.pdf
852 Propidium Iodide, 2µm PDS 890.pdf MSDS 852.pdf
899 R-Phycoerythrin (PE)
PDS 890.pdf MSDS 899.pdf
907 Rhodamine 123 PDS 890.pdf MSDS 907.pdf
904 Rhodamine B PDS 890.pdf MSDS 904.pdf
905 T.M. Rhodamine PDS 890.pdf MSDS 905.pdf
893 Texas Red® (TR)
PDS 890.pdf MSDS 893.pdf

Right Reference Standard™

Each standard consists of a population of microspheres surface labeled with a single fluorochrome at a given intensity level (low, medium, high). The Right Reference Standard™ microspheres approximate the size of human lymphocytes (~7-9µm). With their narrow fluorescence CVs, Right Reference Standard™ products are suitable for alignment purposes. These standards may also be used to QC a specific path of the optical system (laser/filter/PMT), and to establish a unified fluorescence range for a particular detector.

Catalog Code Description Product Data Sheet Material Safety Data Sheet
510 Right Reference Standard™ Fluorescein Low Level
PDS 510.pdf MSDS 510.pdf
511 Right Reference Standard™ Fluorescein Medium Level
PDS 510.pdf MSDS 511.pdf
512 Right Reference Standard™ Fluorescein High Level PDS 510.pdf MSDS 512.pdf
513 Right Reference Standard™ Phycoerythrin Low Level PDS 510.pdf MSDS 513.pdf
514 Right Reference Standard™ Phycoerythrin Medium Level PDS 510.pdf MSDS 514.pdf
515 Right Reference Standard™ Phycoerythrin High Level PDS 510.pdf MSDS 515.pdf
516 Right Reference Standard™ PE-Cy™5 Low Level PDS 510.pdf MSDS 516.pdf
517 Right Reference Standard™ PE-Cy™5 Medium Level PDS 510.pdf MSDS 517.pdf
518 Right Reference Standard™ PE-Cy™5 High Level PDS 510.pdf MSDS 518.pdf
519 Right Reference Standard™ APC Low Level PDS 510.pdf MSDS 519.pdf
520 Right Reference Standard™ APC Medium Level PDS 510.pdf MSDS 520.pdf
521 Right Reference Standard™ APC High Level PDS 510.pdf MSDS 521.pdf

Ultra Rainbow Fluorescent Particles

Ultra Rainbow Fluorescent Particles (by Spherotech™) are internally labeled with multiple fluorophores, enabling excitation at any wavelength from 365-650nm. Ultra Rainbow Fluorescent Particles may be used for general QC purposes for 3-9 color instruments. Ultra Rainbow Fluorescent Particles are available in three sizes: A (20 tests), B (100 tests), and C (280 tests).

Catalog Code Description Product Data Sheet Material Safety Data Sheet
610 Ultra Rainbow Fluorescent Particles, ~3.8µm (3.61-3.99µm)
PDS 610.pdf MSDS 610.pdf
611 Ultra Rainbow Fluorescent Particles, ~10.2µm (8.1-12.0µm) PDS 611.pdf MSDS 611.pdf

QC Windows®

QC Windows® kits for instrument set-up include a blank and one or more bead population(s) surface-labeled with fluorochromes. The kits allow the establishment of upper and lower fluorescence thresholds, the Window of Analysis, for each detector, permitting meaningful data comparison between instruments and over time. These microspheres are ~7-9µm in diameter and approximate the size of human lymphocytes. QC Windows® kits are available in three sizes: A (20 tests), B (100 tests), and C (280 tests).

Catalog Code Description Product Data Sheet Material Safety Data Sheet
845 QC Windows® (FITC/PE)
PDS 845.pdf MSDS 845.pdf
846 QC Windows® (FITC/PE/PE-TR) PDS 845.pdf MSDS 846.pdf
847 QC Windows® (FITC/PE/PE-Cy™5) PDS 845.pdf MSDS 847.pdf
848
QC Windows® (FITC/PE/PE-Cy™5, APC) PDS 845.pdf MSDS 848.pdf

QC3™

QC3™ kits include one or more bead population(s) surface-labeled with fluorochromes for defining an upper fluorescence threshold for each detector, permitting meaningful comparion between instruments and over time. These microspheres are ~7-9µm in diameter and approximate the size of human lymphocytes. QC3™ kits are available in three sizes: A (20 tests), B (100 tests), and C (280 tests).

Catalog Code Description Product Data Sheet Material Safety Data Sheet
841 QC3™ (FITC/PE)
PDS 841.pdf MSDS 841.pdf
842
QC3™ (FITC/PE/PE-TR) PDS 841.pdf MSDS 842.pdf
843 QC3™ (FITC/PE/PE-Cy™5) PDS 841.pdf MSDS 843.pdf
844 QC3™ (FITC/PE/PE-Cy™5, APC) PDS 841.pdf MSDS 844.pdf

FITC/PE Compensation Standard

The FITC/PE Compensation Standard includes four microsphere populations that are ~7-9µm in diameter: an Autofluor™ population, and single populations surface-labeled with FITC, PE, and FITC/PE. The Autofluor™ population is dyed with a low level of fluorophore to approximate the autofluorescence of an unstained resting lymphocyte. This kit is useful for establishing quadrant boundaries and compensation settings for analyses using FITC and PE fluorochromes. The FITC/PE Compensation Standard is available in three sizes: A (20 tests), B (100 tests), and C (280 tests).

Catalog Code Description Product Data Sheet Material Safety Data Sheet
820
FITC/PE Compensation Standard
(Autofluor™/FITC-PE/FITC/PE)
PDS 820.pdf MSDS 820.pdf

Simply Cellular® Compensation Standard

The Simply Cellular® Compensation Standard includes a mixed population of low- and high-binding antibody-coated beads that are ~7-9µm in diameter. Users label aliquots with antibody conjugates of interest to establish suitable compensation settings for a specific analysis.

Catalog Code Description Product Data Sheet Material Safety Data Sheet
550 Simply Cellular® Compensation Standard
(anti-Mouse IgG)
PDS 850.pdf MSDS 550.pdf
551 Simply Cellular® Compensation Standard
(anti-Rat IgG)
PDS 851.pdf MSDS 551.pdf

Viability Dye Compensation Standard

Viability Dye Compensation Standards are suitable for labeling with LIVE/DEAD® stains or similarly-reactive dyes to generate compensation standards for flow cytometric analyses. Beads are not suitable for labeling with DNA stains such as propidium iodide, DAPI, or SYTOX®, and users should contact us for discussion if uncertain as to the compatability of a specific dye or stain.

Catalog Code Description Product Data Sheet Material Safety Data Sheet
450 Viability Dye Compensation Standard, 4µm
PDS 853.pdfMSDS 450.pdf
451 Viability Dye Compensation Standard, 8µm PDS 853.pdfMSDS 451.pdf

Quantum™ MESF

Our Quantum™ MESF kits include microsphere populations that are ~7-9µm in diameter: one blank population and a range of labeled bead populations with increasing amounts of fluorochrome. The assignment of fluorescence intensity in Molecules of Soluble Fluorochrome (MESF) units is performed through direct comparison of fluorescence measurements from solutions of the pure fluorochrome with those from microspheres surface-labeled with the same fluorochrome. In addition to quantitative fluorescence cytometry, Quantum™ MESF kits may be used to assess the detection threshold, resolution, and linearity of the instrument. A free QuickCal® analysis template is provided with each kit to aid in determining the expression level of cells, and for evaluating instrument linearity and detection threshold. Quantum™ MESF kits are available in three sizes: A (20 tests), B (100 tests), and C (280 tests).

Note to FITC MESF Users: We are now offering a single version of Quantum™ FITC MESF rather than the separate Low, Medium, and High Intensity kits. The new version consists of one blank and five labeled bead populations that span the full intensity range previously covered by the three separate kits. See PDS 855, Quantum™ FITC-5 MESF, or 856, Quantum™ FITC-5 MESF Premix, for more information on the kits, and PDS 819, QuickCal® v. 2.3 Data Analysis Program, for details regarding QuickCal® templates.

Catalog Code Description Product Data Sheet Material Safety Data Sheet
555
Quantum™ FITC-5 MESF PDS 855.pdf MSDS 555.pdf
555p Quantum™ FITC-5 MESF (Premix) PDS 856.pdf MSDS 555p.pdf
827 Quantum™ R-PE MESF PDS 827.pdf MSDS 827.pdf
828 Quantum™ PE-Cy™5 MESF PDS 828.pdf MSDS 828.pdf
823 Quantum™ APC MESF PDS 823.pdf MSDS 823.pdf

Quantum™ Simply Cellular®

Quantum™ Simply Cellular® (QSC) kits are comprised of five microsphere populationsthat are ~7-9µm in diameter: one blank and four labeled with increasing amounts of antibody. Each coated population binds a specific number of monoclonal antibodies of the noted species, which is equal to its Antibody Binding Capacity (ABC) value. The investigator labels QSC beads using the same antibodies used to stain cells. In addition to quantitative fluorescence cytometry, QSC kits may be used for compensation. A free QuickCal® analysis template is provided with each kit to aid in determining the expression level of cells, and for evaluating instrument linearity and detection threshold. Quantum™ Simply Cellular® kits are available in three sizes: A (20 tests), B (100 tests), and C (280 tests).

Catalog Code Description Product Data Sheet Material Safety Data Sheet
815 Quantum™ Simply Cellular® anti-Mouse IgG
PDS 815.pdf MSDS 815.pdf
816 Quantum™ Simply Cellular® anti-Human IgG PDS 816.pdf MSDS 816.pdf
817 Quantum™ Simply Cellular® anti-Rat IgG PDS 817.pdf MSDS 817.pdf

Simply Cellular®

Our Simply Cellular® standard consists of a single population of antibody-coated microspheres (~7-9µm in diameter) of known Antibody Binding Capacity (ABC). The population is stained with the user's primary antibody and used in conjunction with a suitable Quantum™ MESF kit for determination of the antibody's effective Fluorophore:Protein (F/P) ratio. This standard may also be used to QC the fluorescence intensity of different antibody lots or clones. Simply Cellular® kits are available in three sizes: A (20 tests), B (100 tests), and C (280 tests).

Catalog CodeDescriptionProduct Data Sheet Material Safety Data Sheet
810 Simply Cellular® anti-Mouse IgG PDS 810.pdf MSDS 810.pdf
812 Simply Cellular® anti-Human IgG PDS 812.pdf MSDS 812.pdf
813Simply Cellular® anti-Rat IgGPDS 813.pdfMSDS 813.pdf

Flow Cytometry Absolute Count Standard™

Our Flow Cytometry Absolute Count Standard™ is a precisely counted population of microspheres for estimating counts of unlabeled cells via flow cytometry. The microspheres are ~7-9µm in diameter. Beads are internally labeled with multiple fluorophores for excitation with common lasers (e.g. 488nm, 633nm) and discrimination from the cell population. By evaluting the ratio of microspheres to cells, the volumetric number of cells may be determined.

Catalog Code Description Product Data Sheet Material Safety Data Sheet
580 Flow Cytometry Absolute Count Standard™ PDS 880.pdf MSDS 580.pdf

Size Calibration Standards Kit

The Size Calibration Standards Kit is comprised of five populations of undyed microspheres in the range of ~4-12µm. Forward scatter channel (FSC) values may be plotted against reported bead diameter to generate a curve that may be used for estimation of the sizes of cells run at the same instrument settings. The Size Calibration Standards Kits are available in two sizes: B (100 tests) and C (280 tests).

Catalog Code Description Product Data Sheet
829 Size Calibration Standards Kit
PDS 829.pdf

QuantumPlex™

QuantumPlex™ kits provide a platform for the design of multiplexed suspension arrays that may be run on standard flow cytometers (488nm or 633nm excitation). Microsphere populations in five-bead kits are encoded with different intensities of Starfire Red™, and microspheres in our ten-bead kits are distinguished by both fluorescence intensity and size. Starfire Red™ exhibits very little carryover into lower wavelengths, leaving other detectors available for determination of positive binding events via common reporters, such as FITC and PE. Carboxyl (COOH), streptavidin, and anti-Mouse IgG surfaces are available. QuantumPlex™ are available in three sizes: A (1mL/population - 5x100 data points), B (5mL/population - 5x500 data points), and C (10mL/population - 5x1000 data points).

Catalog Code Description Product Data Sheet Material Safety Data Sheet
235 QuantumPlex™ COOH 4.4µm, 5 populations
PDS 235.pdf MSDS 235.pdf
238 QuantumPlex™ COOH 5.5µm, 5 populations PDS 235.pdf MSDS 238.pdf
239 QuantumPlex™ COOH 4.4µm and 5.5µm, 10 populations PDS 235.pdf MSDS 239.pdf
215 QuantumPlex™ Streptavidin 4.4µm, 5 populations PDS 215.pdf MSDS 215.pdf
218 QuantumPlex™ Streptavidin 5.5µm, 5 populations PDS 215.pdf MSDS 218.pdf
219 QuantumPlex™ Streptavidin 4.4µm and 5.5µm, 10 populations PDS 215.pdf MSDS 219.pdf
205 QuantumPlex™ anti-Mouse 4.4µm, 5 populations PDS 209.pdf MSDS 205.pdf
208 QuantumPlex™ anti-Mouse 5.5µm, 5 populations PDS 209.pdf MSDS 208.pdf
209 QuantumPlex™ anti-Mouse 4.4µm and 5.5µm, 10 populations PDS 209.pdf MSDS 209.pdf

QuantumPlex™ SP

QuantumPlex™ SP (Single Population) is useful for the development of simplex flow cytometric assays, or for the optimization of attachment chemistry and assay parameters before transitioning to a multiplexed format. Like QuantumPlex™, they are dyed with Starfire Red™ and are suitable for use on standard flow cytometers and carboxyl (COOH), streptavidin, and anti-Mouse IgG surfaces are available. QuantumPlex™ SP are available in two sizes: A (1mL - 100 data points) and B (3mL - 300 data points).

Catalog Code Description Product Data Sheet Material Safety Data Sheet
234 QuantumPlex™ SP COOH 4.4µm
PDS 234.pdf MSDS 234.pdf
237 QuantumPlex™ SP COOH 5.5µm PDS 234.pdf MSDS 237.pdf
214 QuantumPlex™ SP Streptavidin 4.4µm PDS 214.pdf MSDS 214.pdf
217 QuantumPlex™ SP Streptavidin 5.5µm PDS 214.pdf MSDS 217.pdf
204 QuantumPlex™ SP anti-Mouse 4.4µm PDS 207.pdf MSDS 204.pdf
207 QuantumPlex™ SP anti-Mouse 5.5µm PDS 207.pdf MSDS 207.pdf

QuantumPlex™M

QuantumPlex™M (Magnetic) kits consist of five populations of ~6µm highly uniform superparamagnetic microspheres encoded with different intensities of Starfire Red™. Like QuantumPlex™, they are suitable for use on standard flow cytometers. Highly efficient separations may be performed using rare earth magnetic separators. Carboxyl (COOH) and streptavidin surfaces are available. QuantumPlex™M are available in three sizes: A (1mL/population - 5x100 data points), B (5mL/population - 5x500 data points), and C (10mL/population - 5x1000 data points).

Catalog Code Description Product Data Sheet Material Safety Data Sheet
250 QuantumPlex™M COOH, 5 populations
PDS 250.pdf MSDS 250.pdf
252 QuantumPlex™M Streptavidin, 5 populations
PDS 252.pdf MSDS 252.pdf

QuantumPlex™M SP

QuantumPlex™M SP (Magnetic, Single Population) is useful for the development of simplex flow cytometric assays, or for the optimization of attachment chemistry and assay parameters before transitioning to a multiplexed format. Like QuantumPlex™M, they are ~6µm highly uniform superparamagnetic microspheres dyed with Starfire Red™ and are suitable for use on standard flow cytometers. Carboxyl (COOH) and streptavidin surfaces are available. QuantumPlex™M SP are available in two sizes: A (1mL - 100 data points) and B (3mL - 300 data points).

Catalog Code Description Product Data Sheet Material Safety Data Sheet
251 QuantumPlex™M SP COOH PDS 251.pdf MSDS 251.pdf
253 QuantumPlex™M SP Streptavidin PDS 253.pdf MSDS 253.pdf

QuickCal® Analysis Template, v. 2.3

QuickCal® constructs a calibration curve associating fluorescence channel values to standardized fluorescence intensity units. The channel value corresponding to the kit's blank bead is converted to the appropriate standardized fluorescence intensity unit (MESF or ABC); this will be the instrument's detection threshold for the specific reporter and detector. For instructions regarding QuickCal, please see Product Data Sheet 819, QuickCal® v. 2.3 Data Analysis Program.